MSD (Meso Scale Discovery) is a method similar to ELISA except MSD uses electrochemiluminescence (ECL) as a detection technique as opposed to a colorimetric reaction employed by ELISA. Meso Scale Discovery has developed proprietary technology for the measurement of various molecules in different biological samples including but not limited to serum, plasma, CSF, cell culture supernatants, sputum..

MSD Multiplex immunoassays allow simultaneous detection and quantification of multiple analytes in a single sample from a variety of biological specimens.

V-PLEX Human Cytokine 30/36-Plex Kit

The Human Cytokine 30/36-Plex Panel Kit consists of 4 independent 10-plex panels—Proinflammatory Panel 1 (human), Cytokine Panel 1 (human), TH17 Panel 1 (human), and Chemokine Panel 1 (human)—that detect secreted biomarkers in a variety of tissues and body fluids. The panels are optimized to achieve the highest level of performance from each assay, providing efficient biomarker screening and profiling without compromising performance. These panels are composed of assays against human cytokines and chemokines that are involved in many biological processes such as inflammation, the Th1/Th2 pathway, chemotaxis, the Th17 pathway, angiogenesis, and immune system regulation. As a result of their association with such a wide number of diseases, these assays are the subject of drug discovery projects, diagnostics development, and basic research. The 36-plex panel can be initially used as a screening panel to identify relevant biomarkers that can then be assembled into a custom panel for long-term studies.

  • Sample type: Human urine, serum, plasma, and cell culture supernatants.
  • Analyte(s): 30 Plex Panel- Eotaxin, Eotaxin-3, GM-CSF, IFN-γ, IL-1α, IL-1β, IL-2, IL-4, IL-5, IL-6, IL-7, IL-8, IL-8 (HA), IL-10, IL-12/IL-23p40, IL-12p70, IL-13, IL-15, IL-16, IL-17A, IP-10, MCP-1, MCP-4, MDC, MIP-1α, MIP-1β, TARC, TNF-α, TNF-β, VEGF-A. 36 Plex Panel- Eotaxin, Eotaxin-3, GM-CSF, IFN-γ, IL-1α, IL-1β, IL-2, IL-4, IL-5, IL-6, IL-7, IL-8, IL-8 (HA), IL-10, IL-12/IL-23p40, IL-12p70, IL-13, IL-15, IL-16, IL-17A, IL-21, IL-22, IL-23, IL-27, IL-31, IP-10, MCP-1, MCP-4, MDC, MIP-1α, MIP-1β, MIP-3α, TARC, TNF-α, TNF-β, VEGF-A

V-PLEX Metabolic Panel 1 Human Kit


The V-PLEX platform offers analytically validated single- and multiplex assay kits. Developed under rigorous design control, V-PLEX kits provide accurate and reproducible results, with consistency from lot to lot. The V-PLEX Metabolic Panel 1 (human) Kit includes seven (7) biomarkers that are associated with metabolic disease. 
  • Sample type: Human Cell Culture Supernatant, P800 Plasma, Serum. 
  • Analyte(s): C-Peptide, GIP (active), GLP-1 (active), Glucagon, Insulin, Leptin, PP


V-PLEX Human Biomarker 54-Plex Kit

The 54 assays in the V-PLEX Human Biomarker 54-Plex are provided in seven multiplex panels— Proinflammatory Panel 1 (human), Cytokine Panel 1 (human), Chemokine Panel 1 (human), Angiogenesis Panel 1 (human), TH17 Panel 1 (human), Cytokine Panel 2 (human), and Vascular Injury Panel 2 (human). The panels are optimized to achieve the highest level of performance from each assay, providing efficient biomarker screening and profiling without compromising performance. These panels are composed of assays against human cytokines and chemokines that are involved in many biological processes such as inflammation, the Th1/Th2 pathway, chemotaxis, the Th17 pathway, angiogenesis, and immune system regulation. As a result of their association with such a wide number of diseases, these assays are the subject of drug discovery projects, diagnostics development, and basic research. The seven multiplex panels can be selected/performed individually as well depending on your project's need.

  • Sample type: Human Serum, Plasma, Cell Culture Supernatant, Urine
  • Analyte(s):  CRP, Eotaxin, Eotaxin-3, FGF (basic), GM-CSF, ICAM-1, IFN-γ, IL-1α, IL-1β, IL-1RA, IL-2, IL-3, IL-4, IL-5, IL-6, IL-7, IL-8, IL-8 (HA), IL-9, IL-10, IL-12/IL-23p40, IL-12p70, IL-13, IL-15, IL-16, IL-17A, IL-17A/F, IL-17B, IL-17C, IL-17D, IL-21, IL-22, IL-23, IL-27, IL-31, IP-10, MCP-1, MCP-4, MDC, MIP-1α, MIP-1β, MIP-3α, PlGF, SAA, TARC, Tie-2, TNF-α, TNF-β, TSLP, VCAM-1, VEGF-A, VEGF-C, VEGF-D, VEGFR-1/Flt-1.

U-PLEX Combinations for Immuno-Oncology Research
U-PLEX Combos represent popular combinations of assays, grouped into separate catalog numbers for ordering convenience.


Analytes in each combinations:

  • Angiogenesis Combo 1: FGF (basic), PlGF, Tie‑2, VEGF‑A, VEGF‑D.
  • CAR-T Cell Combo 1: GM‑CSF, Granzyme A, Granzyme B, IFN‑γ, IL‑2, TNF‑α.
  • Effector Cell Checkpoint Combo 1: CD27, CD28, CD40L (soluble), CTLA‑4, GITR/TNFRSF18, HAVCR2/TIM‑3, LAG3, OX40/TNFRSF4, PD1 (epitope 1), TIGIT.
  • Macrophage M1 Combo 1:  IL-1β, IL-6, IL-12p70, IL-18, IL-23, IP-10, MCP-1, MIP-1α, TNF-α.
  • Macrophage M2 Combo 1:  Eotaxin-2, IL-4, IL-10, IL-13, M-CSF, MDC, TARC.
  • Target Cell Checkpoint Combo 1: CD276/B7‑H3, GITRL/TNFSF18, PD‑L1 (epitope 1), PD‑L2
  • Immuno-Oncology Group 1 111-Plex: BAFF, BAFF‑R/TNFRSF13C, BDNF, BCMA/TNFRSF17, CD20, CD27, CD276/B7‑H3, CD28, CD40L (soluble), C‑Peptide, CTACK, CTLA‑4, ENA‑78, Eotaxin, Eotaxin‑2, Eotaxin‑3, EPO, FGF (basic), FGF‑23, FLT3L, Fractalkine, FSH, G‑CSF, Ghrelin (active), Ghrelin (total), GIP (active), GIP (inactive), GIP (total), GITR/TNFRSF18, GITRL/TNFSF18, GLP‑1 (active), GLP‑1 (inactive), GM‑CSF, gp130 (soluble), Granzyme A, Granzyme B, GRO‑α, HAVCR2/TIM‑3, I‑309, IFN‑α2a, IFN‑β, IFN‑γ, IL‑1α, IL‑1β, IL‑1RA, IL‑2, IL‑2Rα, IL‑3, IL‑4, IL‑5, IL‑6, IL‑7, IL‑8, IL‑9, IL‑10, IL‑12/IL‑23p40, IL‑12p70, IL‑13, IL‑15, IL‑16, IL‑17A, IL‑17A/F, IL‑17C, IL‑17D, IL‑17E/IL‑25, IL‑17F, IL‑18, IL‑21, IL‑22, IL‑23, IL‑27, IL‑29/IFN‑λ1, IL‑31, IL‑33, Insulin, IP‑10, I‑TAC, LAG3, Leptin, LH, MCP‑1, MCP‑2, MCP‑4, M‑CSF, MDC, MIF, MIP‑1α, MIP‑1β, MIP‑5, OX40/TNFRSF4, PD1 (epitope 1), PD1 (epitope 2), PD‑L1 (epitope 1), PD‑L2, PIGF, PP, Proinsulin, PYY (total), RANKL/TNFSF11, SDF‑1α, Tie‑2, TIGIT, TLR1, TNF‑α, TNF‑β, TPO, TRAIL, TSLP, VEGF‑A, VEGF‑D, YKL‑40.

If you prefer to have another panel of analytes for your project please contact us as well. Our bioscientists will help you to design a custom panel specially fitted for the need of your project end-points.